Troubleshooting - Omron V530-R160E User Manual

2d code reader
Hide thumbs Also See for V530-R160E:
Table of Contents

Advertisement

Troubleshooting

Connection Errors
Symptoms
The POWER indicator is not lit.
The Video Monitor is blank.
The Video Monitor image is not clear.
Cannot make key inputs on the Con-
sole.
Camera images are not displayed.
(when using a Camera with a light)
Camera images are not displayed.
(when using a standard CCTV lens
and light.)
The images on the monitor are recog-
nized but codes are hard to read.
Causes and remedies
• The power supply is not connected properly.
• The power supply voltage is below the allowed range
(20.4 to 26.4 VDC).
• The power to the Video Monitor is not ON.
• The monitor cable is not connected properly.
• The Video Monitor is malfunctioning.
• (When the LCD monitor is used)
The power supply is not sufficient for the LCD moni-
tor.
• There is electrical noise entering from the power sup-
ply or cables.
• The Monitor Cable is not connected properly.
• The Console Cable is not correctly connected.
• The camera cable is not properly connected.
• The Light Cable is not properly connected.
• The lens cap has not been removed.
• The Camera Cable is not properly connected.
• The lens diaphragm is opened or closed too far.
• The shutter speed is not suitable.
• The light method is not suitable.
• Refer to the entry for the error code in Error Codes
and Countermeasures. Change the setting condi-
tions and adjust the camera and lighting.
SECTION 9
Troubleshooting
p.45
p.43
p.43
p.43
p.43
p.93
p.49
p.253
V530-R160
261
Operation Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

V530-r160ep

Table of Contents