Omron V530-R160E User Manual page 128

2d code reader
Hide thumbs Also See for V530-R160E:
Table of Contents

Advertisement

SECTION 5
Setting Reading Conditions
 Saving Reading Data (Store Data to MemCard)
The reading results recorded in the trend monitor can be saved in a Memory Card. Since the
data is saved in CSV format, it can be edited on a PC.
Data to be saved include statistical data, the read data and times of occurrence when alarms and
NG results occurred (up to 1000 events), and the reading results on the graph (up to 1000
results).
When Store data to MemCard is turned ON, a directory designated TRENDMON is automatically
created in the root directory of the Memory Card, and the data is saved under this directory.
 CSV Format
<Maximum> <Minimum> <Average> <Maximum> <Minimum> <Average> <Measure count> <NG count> <Warning count>
: Statistic data
1
The maximum value, minimum value, and average value are saved for correlation first and then con-
trast.
: Reading results when alarms and NG results occurred
2
Up to 1000 NG results starting from the most recent are saved.
: Reading results on the graph
3
Up to 1000 results starting from the most recent data are saved.
V530-R160
126
Operation Manual
0. <Corr.> <Cont.> <Time>
1. <Corr.> <Cont.> <Time>
2. <Corr.> <Cont.> <Time>
35. <Corr.> <Cont.> <Time>
0. <Corr.> <Cont.> <Time>
1. <Corr.> <Cont.> <Time>
46. <Corr.> <Cont.> <Time>
The data is saved.
1
2
3

Advertisement