The screen for setting the communications specifi-
cations is displayed.
5.
Make the settings for each item.
6.
Select End.
The setting will be registered and the screen in
Set items and their details
Item
Interface
Baud rate (See note 1.)
Data length
Parity bits
Stop bits
Header
Footer
FCS
Mode
Protocol (See note 2.)
The asterisk (*) indicates the default setting.
Note 1: Since communications speeds higher than 20 kbps are not defined with the RS-232C standard,
depending on the cable length, if 38400 bps or a higher setting is selected it may not be possible to
perform communications properly. If this happens, change the setting to 19200 bps or lower.
Note 2: The XMODEM (-1K) protocol is not supported.
Make the following settings when using the save and load commands (@CL, @CS, etc.)
Data length
Parity bits
Stop bits
Flow control
4.
RS-232C*, RS-422
2400, 4800, 9600, 19200, 38400*,
57600, 115200 (bps)
7, 8* (bit)
None*, Odd, Even
1*, 2 (bit)
None*, STX, ESC
CR*, LF, CR+LF, ETX
OFF*, ON
Select Normal. (Normal*, Host link)
XMODEM*, ZMODEM
Item
Setting
8 bits
None
1 bit
None
Communication with the Host
will return.
Selection
Set the same settings as those set for
the personal computer.
Refer to page 208.
SECTION 8
V530-R160
207
Operation Manual