Omron V530-R160E User Manual page 236

2d code reader
Hide thumbs Also See for V530-R160E:
Table of Contents

Advertisement

SECTION 8
Communication with the Host
 TRIG A Signal as Reading Trigger
The trigger is used to cause the V530-R160 to read data and the data is written to the program-
mable controller.
Set the Read Area to None.
TRIG A
Executes reading.
Writes data to Write Area.
Time the input of TRIG A considering the image processing time and data output time, allowing suf-
ficient leeway. An error will occur if the next input occurs before communications have been com-
pleted.
V530-R160
234
Operation Manual
F160
[Write Area]
Controller
While the command is being executed,
the BUSY signal of the parallel I/O interface is ON.
END
Programmable Controller
Unit number: 00 (Fixed)
Returns write completed
response.
A timeout error occurs if there is no response within
5 seconds and it is assumed that the line is broken or
the programmable controller is not working correctly.
An error message is displayed on the screen and the
ERR signal of the parallel I/O interface is turned ON.

Advertisement

Table of Contents