Check The Hydraulic Return Filter Condition Indicator (If Equipped); Perform Engine Maintenance - Deutz 1011F Models - Genie GS-3384 Service Manual

From serial number 40001 to gs8405-40832
Hide thumbs Also See for GS-3384:
Table of Contents

Advertisement

September 2005
REV C
A-14
Check the Hydraulic Return Filter
Condition Indicator (if equipped)
Genie specifications require that
this procedure be performed every
100 hours of operation.
Maintaining the hydraulic return filter in good
condition is essential to good system performance
and safe machine operation. The filter condition
indicator will show when the hydraulic flow is
bypassing a clogged filter. If the filter is not
frequently checked and replaced, impurities will
remain in the hydraulic system and cause
component damage.
In extreme cold conditions,
20°F / -6°C and below, warm the
engine for 5 minutes before
operating to prevent hydraulic
system damage.
1 Start the engine from the platform controls.
2 Press the high idle button at the platform
controls to allow the engine to run at high idle.
3 Open the function manifold tray door and locate
the hydraulic tank return filter behind the entry
ladder.
4 Inspect the filter condition indicator gauge.
Result: The needle on the gauge should be
operating in the green area. If the needle is in
the red area, this indicates that the hydraulic
filter is being bypassed and the filter should be
replaced. See B-15, Replace the Hydraulic
Tank Return Filter.
Part No. 82259
Section 3 • Scheduled Maintenance Procedures
CHECKLIST A PROCEDURES
A-15
Perform Engine Maintenance -
Deutz 1011F Models
Engine specifications require that
this procedure be performed every
125 hours or quarterly, whichever
comes first.
Required maintenance procedures and additional
engine information is available in the Deutz 1011F
Operation Manual (Deutz part number 0297 9683).
Deutz 1011F Operation Manual
Genie part number
GS-3384
52883
3 - 15