17 Clean up any fuel that may have spilled during
this procedure.
18 Install the fuel pump mounting plate.
19 Turn the key switch to ground control and pull
out the red Emergency Stop buttons to the
position at both the ground and platform
controls.
20 Start the engine from the ground controls.
Inspect the fuel filter and hoses for leaks.
Explosion and fire hazard. If a fuel
leak is discovered, keep any
additional personnel from entering
the area and do not operate the
machine. Repair the leak
immediately.
21 Install the access plate behind the fuel and
hydraulic tank tray.
22 Raise the platform and return the safety arm to
the stowed position.
23 Lower the platform to the stowed position.
Part No. 82259
Section 3 • Scheduled Maintenance Procedures
E-3
Perform Engine Maintenance -
Deutz 1011F Models
ON
Required maintenance procedures and additional
engine information is available in the Deutz 1011F
Operation Manual (Deutz part number 0297 9683).
Deutz 1011F Operation Manual
Genie part number
GS-3384
CHECKLIST E PROCEDURES
Engine specifications require that
this procedure be performed every
2000 hours or two years,
whichever comes first.
52883
3 - 59