Table of Contents

Advertisement

September 2005
REV C
4 Locate the level sensor behind the ground
control panel.
5 Disconnect the platform controls from the
machine at the platform.
6 Open the large ground control panel door and
locate the Electronic Control Module (ECM)
wire harness to platform controls wire harness
connection below the ground controls.
7 Tag and disconnect the platform controls wire
harness from the ECM wire harness.
8 Securely connect the platform controls to the
ECM wire harness.
If you are not installing a new level sensor,
proceed to step 13.
Part No. 82259
Install the level sensor:
9 Tag and disconnect the wire harness from the
level sensor.
10 Remove the three level sensor retaining
fasteners. Remove the level sensor from the
machine.
11 Install the new level sensor onto the machine
with the "X" on the level sensor base closest to
the steer end of the machine. Install and tighten
the level sensor retaining fasteners.
Tip-over hazard. The tilt level
sensor must be installed with the
"X" on the level sensor base
closest to the steer end of the
machine. Failure to install the tilt
level sensor as instructed could
result in the machine tipping over
causing death or serious injury.
d
X
Y
c
Level sensor - models without outriggers
a
b
c
d
GS-3384
Section 4 • Repair Procedures
GROUND CONTROLS
MODELS
WITH
OUTRIGGERS
chassis
level sensor
"Y" indicator
"X" indicator
a
b
4 - 57