Section 4 • Repair Procedures
GROUND CONTROLS
15 Install the new level sensor onto the machine
with the "Y" on the level sensor base closest to
the steer end of the machine. Install the level
sensor retaining fasteners.
Tip-over hazard. The tilt level
sensor must be installed with the
"Y" on the level sensor base
closest to the steer end of the
machine. Failure to install the tilt
level sensor as instructed could
result in the machine tipping over
causing death or serious injury.
MODELS
WITHOUT
OUTRIGGERS
a
Y
X
b
Level sensor - models without outriggers
a
chassis
b
level sensor
c
"X" indicator
d
"Y" indicator
4 - 52
16 Connect the wire harness to the level sensor.
17 Pull out the red Emergency Stop button to the
on position at the platform controls.
18 Tighten the level sensor adjusting fasteners
until the bubble in the top of the level sensor is
centered in the circles.
Be sure there are threads showing
through the top of the adjusting
fasteners.
Result: The tilt sensor alarm should not sound.
19 Lower the platform to the stowed position.
20 Raise the machine slightly.
21 Remove the blocks from under both wheels.
22 Lower the machine and remove the jack.
23 Remove the blocks from the wheels at the
non-steer end of the machine.
24 Block the wheels at the steer end of the
machine.
d
25 Center a lifting jack under the drive chassis at
the non-steer end of the machine.
c
26 Raise the machine approximately
12 inches / 30 cm.
27 Place a 10.28 x 10 x 10 inch / 26.11 x 25 x 25
cm thick steel block under both wheels at the
non-steer end of the machine.
28 Lower the machine onto the blocks.