Section 4 • Repair Procedures
PLATFORM CONTROLS
7 To confirm the settings, pull out the red
Emergency Stop button to the on position at
both the ground and platform controls and turn
the key switch to ground control. Do not start
the engine.
8 Move and hold the platform up/down toggle
switch in the up direction and activate the
function enable toggle switch from the ground
controls.
Result: The LED diagnostic readout window,
located on the ground control panel, will display
a configuration number without the dot
illuminated. This configuration number indicates
the current configuration of the machine.
SYSTEM
20 AMP
HOUR METER
Function
Enable
c
b
a
red Emergency Stop button P1
b
platform up/down toggle switch TS66
c
function enable toggle switch TS67
9 Release the toggle switches, push in the red
Emergency Stop button to the off position at
both the ground and platform controls and turn
the key switch to the off position.
4 - 12
Refer to the appropriate
Genie service manual
for code descriptions.
a
Stop
GS-3384
DIP Switch Function Definitions
If replacing the circuit board, note
the toggle positions on the DIP
switches. Set the DIP switches on
the new circuit board to the same
configuration of the old one.
Gasoline/LPG: Indicates that the machine is
gasoline/LPG powered.
Diesel: Indicates that the machine is diesel
powered.
Motion Alarm: The motion alarm will sound when
operating any function.
Lift/Drive Cut Out: This cuts out lift and drive
functions when the machine exceeds the rating on
the serial plate. Required for Europe and Australia.
Installed on all machines.
Motion Beacon: The motion beacon option
flashes only when operating a function.
Overload: This cuts out all functions when the
pressure sensor is overloaded. The Emergency
Stop button must be cycled before any function
can be resumed. Required for Europe.
Descent Delay: This option halts descent at
approximately 12 feet / 3.6 m. All controls must be
released for 4 to 6 seconds before descent is
re-enabled. Required for Europe.
No Simultaneous Operation: This does not allow
the machine lift and drive functions to operate at
the same time. Required for Europe.
September 2005
REV C