September 2005
REV C
1-4
Software Configuration
(before serial number GS8403-40213)
How to Configure the Software
The Electronic Control Module (ECM) contains
programming for all configurations of the GS-84.
Models before serial number GS8403-40213 can
be adjusted to a different configuration by changing
the combination of the DIP switch settings, located
on the circuit board inside the platform control box.
DIP switches have two positions - on or off. When
reading the DIP switch code in the DIP Switch
Codes Chart on the next page, the on and off are
represented by the numbers 1 (on) and 0 (off).
If replacing the circuit board, note
the toggle positions on the DIP
switch. Set the DIP switch on the
new circuit board to the same
configuration as the old one.
1 Push in the red Emergency Stop button to the
off position at the ground and platform controls.
Turn the key switch to the off position.
2 Remove the fasteners securing the lid of the
platform controls and open the platform control
box.
Part No. 82259
3 Rotate the platform controller box in the position
shown to correctly identify the configuration of
the DIP switch settings.
4 Open the controller box lid and locate the DIP
switch on the circuit board. Move the DIP
switch settings to correspond with the
configuration of the machine options, indicated
in the chart. See 1-4, DIP Switch Codes Chart.
f
e
ON (1)
OFF (0)
a
b
c
d
e
f
5 Apply dielectric grease to the DIP switch after
setting the configuration.
6 Close the lid and install the platform control box
lid fasteners.
GS-3384
Section 4 • Repair Procedures
PLATFORM CONTROLS
ON
DIP
1 2
3
4
5
6
7
8
red Emergency Stop button P2
DIP switch SW25
platform control box
enlarged view of DIP switch SW25
circuit board U3
joystick controller JC1
a
b
c
d
4 - 11