Section 4 • Repair Procedures
GROUND CONTROLS
10 Press the lift function enable button to activate
or deactivate the motion beacons option OR
use the yellow platform down arrow to scroll to
overload.
For this option to function
correctly, the machine must be
equipped with flashing beacons.
Result:
is showing in the diagnostic
OVERLOAD ON
display window.
Result:
OVERLOAD OFF
diagnostic display window. Press the lift
function enable button to activate the overload
option.
For CE models, the overload
option should be activated or in
the
position.
ON
11 Use the yellow platform down arrow to scroll to
sim operation.
Result:
SIM OPERATION OFF
diagnostic display window.
Result:
SIM OPERATION ON
diagnostic display window. Press the lift
function enable button to deactivate the sim
operation option.
For CE models, the sim operation
option should be deactivated or in
the
OFF
4 - 50
is showing in the
is showing in the
is showing in the
position.
12 Use the yellow platform down arrow to scroll to
return to the main menu.
Result:
RETURN TO MAIN MENU
diagnostic display window.
13 Press the lift function enable button.
Result:
SELECT OPTIONS
diagnostic display window.
14 Push in the red Emergency Stop button to the
off position at the ground controls.
GS-3384
September 2005
REV C
is showing in the
is showing in the
Part No. 82259