Platform

How to Remove the Platform
Bodily injury hazard. This
procedure requires specific repair
skills, lifting equipment and a
suitable workshop. Attempting this
procedure without these skills and
tools could result in death or
serious injury and significant
component damage. Dealer
service is required.
Perform this procedure with the
platform in the stowed position
and the platform extension deck(s)
fully retracted and locked in
position.
1 Start the engine from the ground controls and
raise the platform approximately 18 feet / 5.5 m
from the ground.
2 Release the safety arm latch, lift the safety arm
and rotate to a vertical position. Lock the safety
arm in position.
Be sure that the safety arm is
locked in the vertical position.
3 Lower the platform onto the safety arm. Turn
the machine off.
Crushing hazard. Keep hands
clear of the safety arm when
lowering the platform.
Part No. 82259

Platform Components

4 Cut the zip ties that secure the power to
platform wiring to the bottom of the platform.
Component damage hazard. Be
sure not to cut the power to
platform wiring.
5 Cut the zip ties that secure the platform controls
wiring to the bottom of the platform.
Component damage hazard. Be
sure not to cut the platform
controls wiring.
6 Start the engine from the ground controls.
7 Raise the platform slightly and return the safety
arm to the stowed position.
8 Lower the platform to the stowed position. Turn
the machine off.
9 Locate the quick disconnect for the platform
controls under the platform at the steer end of
the machine.
10 Tag and disconnect the platform controls from
the control cable at the steer end of the
machine.
11 Remove the platform control box from the
platform and lay it off to the side.
12 Remove the mounting fasteners that hold the
platform controls quick disconnect plug to the
platform.
13 Lay the platform controls wiring off to the side.
Component damage hazard. The
platform controls wiring can be
damaged if it is kinked or pinched.
14 Remove the AC power to platform outlet
bracket mounting fasteners.