September 2005
REV C
How to Adjust the High Torque
Drive Speed
Tip-over hazard. Do not adjust the
lift and/or drive speed higher than
specified in this procedure. Setting
drive speed greater than
specifications could cause the
machine to tip over resulting in
death or serious injury.
On machines with software
revision B1 or lower, high torque
drive speeds in forward and
reverse are simultaneously
adjusted, resulting in both
directions of travel operating at the
same speed.
On machines with software
revision C0 or higher, the high
torque forward drive speed and
the high torque reverse drive
speed may be adjusted
independent of one another. See
5-2, How to Determine the
Revision Level.
Models with software revision B1 or lower:
1 Pull out the red Emergency Stop button to the
on position at the platform controls.
2 Push in the red Emergency Stop button to the
off position at the ground controls.
3 Turn the key switch to ground control.
Part No. 82259
a
a
b
c
d
4 Press and hold both the blue platform up and
yellow platform down buttons. Pull out the red
Emergency Stop button to the on position at the
ground controls.
Result:
TUNE SPEEDS
display window. The ECM is now in
programming mode.
5 Press the lift function enable button.
6 Use the yellow platform down arrow to scroll to
max high torque drive.
Result:
MAX HIGH TORQUE DRIVE
diagnostic display window.
7 Press the lift function enable button.
8 Press the yellow platform down button to
decrease the drive speed or press the blue
platform up button to increase the drive speed.
Refer to Section 2, Specifications.
The performance achieved should
always be within specifications.
9 Press the lift function enable button.
10 Push in the red Emergency Stop button to the
off position at the ground controls.
GS-3384
Section 4 • Repair Procedures
GROUND CONTROLS
diagnostic display
blue platform up button
lift function enable button
yellow platform down button
is showing in the diagnostic
is showing in the
b
c
d
4 - 39