Siemens SINUMERIK 840D sl Operating Manual page 369

Sinumerik integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Property
Description
K no.
The CU-related SINAMICS component number
is displayed or specified.
K status
Setting options:
● HW available, inactive (p1x5=0)
● HW available, active (p1x5=1)
● HW not available, inactive (p1x5=2)
OEM ID
Identifier of the component in the catalog of the
machine manufacturer.
DO status
DO variable
The specified DO variable is assigned to this
component. The drop-down list lists all DO var‐
iables available in the DO variable list (see Topo
- menu functions (Page 360)) that are permitted
on this component in accordance with their type.
DO type
Assignment of a DO to a component type.
DO number
DO number via which a drive object is ad‐
dressed.
DO name
Freely selectable name for a drive object.
DO status
Setting options:
● 0 inactive, available
● 1 active, available
● 2 not available
Encoder number
Specifies the number of the Encoder Data Set
(EDS) to which this encoder evaluation with its
associated encoder data set is assigned in the
referenced DO.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD
Create MyConfig - Topo
Note
The component number can be edited. The follow‐
ing rules apply:
● The SINAMICS component number range is
between 1 and 199.
● Component number 1 is assigned automatically
for control units and cannot be edited.
● In relation to a control unit, the component
number must be unique.
● For all other components, the component
number can be in the range from 2 to 193 in
relation to a control unit (CU320, NCU or NX)
(6 K numbers are reserved for CU-LINK DOs).
● In the topology configurator, the component
numbers can be automatically reassigned or
added via the context menu when selecting a
bus or slave.
● The default value is "HW available, active."
● Cannot be changed for CU320 and NCU control
units.
● Also cannot be changed for DOs that only
consist of one component.
Only numbers can be used.
Not available for device classes that do not consti‐
tute a drive object, e.g. motor, encoder.
A DO variable name must start with a letter or an
underscore and comprises the characters A-Z_0-9.
Is a property of the DO variable and can only be
modified via the DO variable list (Page 370).
Is a property of the DO variable and can only be
modified via the DO variable list (Page 370).
Is a property of the DO variable and can only be
modified via the DO variable list (Page 370). DO
names can have a maximum of 24 ASCII charac‐
ters.
● The default value is "1 active, available".
● The "Active" status cannot be changed for the
DO types "Integrated (NCU)" and "SINAMICS
S".
Only permissible in conjunction with a DO variable
reference. Only for the "Sensor module" device
class.