DO variables
The following properties are available for the "DO variables", which are activated when the
package is executed:
List
The following can be defined for a DO variable:
Parameter
DO variable
DO type
DO No.
DO name
Description
The assignment of the DO number, the DO name and the description is optional.
The DO variable list is not used for verifications by Expert during the verification run.
The DO variable list from Expert is only used during package execution if the comparison
topology or user-specified topology is not used. The DO variable list is therefore only of
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD
The
button opens the "DO list" dialog.
Enter the "DO variable" and its corresponding data here:
● DO type
● DO No.
● DO name
● Description
Or you link or import an externally stored file.
Description
Unique name within the package (without
specifying Up.)
Type depending on the selected category:
Category
Type
Control Unit
Integrated (NCU)
SINAMICS
Extended (NX)
Line Module
ACTIVE INFEED CON‐
TROL
SMART INFEED CON‐
TROL
BASIC INFEED CONTROL
Motion Control
SERVO
Terminal Mod‐
TM31
ule
Terminal Board TB30
Hub Module
DMC20 / DME20
CULINK
CULINK
DO number to be assigned to the drive object.
NOTE
No number may be assigned for the CU_Link
DO type.
DO name to be assigned to the drive object.
Additional information for the operator.
Create MyConfig - Expert
4.4 Project folder
Character
Characters:
A-z_0-9
1-54
Characters (max.
24):
A-z_0-9
-
173