Display associated system variables button
You open the "SINAMICS topology - system variables" dialog via the button
associated system variables). All system variables to be used under "SINAMICS topology" are
listed here.
Information on the System variables·can be found in the System variables for the SINAMICS
topology dialog (Page 292) section.
Further general information on the system variables can be found in the Reference list system
variables (Page 283) section.
Dialog
More detailed information about the property group "Dialog" can be found under Package
configuration (configuration) (Page 121).
Axis-drive assignment
The following properties are available for the "axis-drive assignment", which are activated when
the package is executed:
Activation
Setting disabled
An Axis-drive assignment can only be defined in the Comparison topology and User-specified
topology variants because only these variants use an appropriate configuration from Topo.
As a prerequisite, this Axis-drive assignment must have been configured and activated in Topo
for the comparison or User-specified topology.
By activation, with equal rights, of the Axis-drive assignment in Topo, there is a guarantee that
not only the expert for Expert, but also the expert for Topo will agree to this assignment. And
furthermore, it is possible for the project engineer for Expert and the operator during package
execution to deactivate this automatic Axis-drive assignment without having to open and edit
the topology files.
Comparison topology (*.ust)
Note
Prerequisite for comparison topology
On the "SINAMICS topology" dialog page, a comparison topology is always used if, on the
System configuration dialog page under DRV archive data / Drive configuration, for "Origin of
data" Initial state, Automatic configuration, or Offline archive has been selected.
With the comparison topology, the Drive-CLiQ wiring and components are checked based on
the SINAMICS target topology from the DRV archive.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD
Yes
Here, you specify whether the "axis-drive assignment"
is to be activated.
No
Yes
By selecting "Yes", the project engineer can block a
change of the "activation" property by the operator dur‐
No
ing package execution.