When copying and navigating, an error-tolerant procedure is used. A check
is first made as to whether the name corresponds to a data management
name. If this is the case, then the system uses the information from data
management. Otherwise, a check is made as to whether this name exists
at the operating system level and is not assigned to another data manage‐
ment entry. If this is the case, then the system uses the information from
the operating system.
For copying of PLC blocks, they must be specified according to the archive
naming convention.
The naming convention has the following format: TTNNNNN, whereby TT
stands for the hexadecimal type, and NNNNN for the decimal number of the
block. When necessary, both should be filled up with leading zeros to obtain
2 or 5 positions respectively.
PLC block types:
Organization block
08 - OB
Data block
0A - DB
System data block
0B - SDB
Function
0C - FC
Function block
0E - FB
For easier identification of the function block types, the
plain-text names in parentheses are shown behind each
of the naming conventions.
The blocks must be stored in TTNNNNN format.
In contrast to Windows, the file system used on the NCU differentiates be‐
tween upper and lower case.
For the "Operate" target area, create the folders that define how to proceed
with your data via the context menu.
This folder is used to define for which SINUMERIK Operate the files are to
be copied.
Possible folders at this point are:
ALL
The data is copied to all Operates, on NCU and PCU, that
are accessible.
NCU
The data is only copied to the Operate on the NCU.
NCU(PCU)
The data is only copied to the NCU. If no NCU is available,
it is copied to the PCU.
PCU
The data is only copied to the Operate on the PCU.
PCU(NCU)
The data is only copied to the PCU. If no PCU is available,
it is copied to the NCU.
Below these folders, you now create the path for the files to be copied.