Siemens SINUMERIK 840D sl Operating Manual page 113

Sinumerik integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Name
In the table column under "Name", dialog pages with a black checkbox can be activated or
deactivated for "Editing" directly in the dialog list or via the property "Edit" in the property field.
Dialog pages with a gray checkbox are always required to execute the package, in accordance
with the configuration of the areas in the Package tab, and cannot be deselected.
Editing mode for all dialogs
By right-clicking on one of the table columns (Name, Mode or Messages) or on a dialog page,
you can uniformly define the Mode property for all dialogs: "Editing mode for all dialogs".
The following options are offered and are activated when the package is executed:
Manual
Automatic
Progress
Display messages for all dialogs
Also by right-clicking on one of the table columns (Name, Mode or Messages) or on a dialog
page, you can uniformly define the Messages property for all dialogs: "Display messages for
all dialogs".
The following options are available:
Error
Errors and warnings
All
Using the dialog list, you can centrally view the editing mode and message display for all
dialogs, and select individually or for all dialogs (context menu).
Dialog pages for the Dialogs tab
The following dialog pages are run through chronologically during package execution.
In the following sections, the property groups and the setting options for the respective dialog
pages are described.
Finally, the configured dialog page is shown how it is displayed for the operator or
commissioning engineer during package execution.
All configurable dialog pages have multiple property groups. All dialog pages have the following
two property groups:
● Dialog
● Operating instructions
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD
The dialog page is completely displayed, the operator can make changes
and must trigger the dialog page advance or execution.
The dialog page is completely displayed, however, the operator cannot make
any changes and it is executed automatically.
Processing is analogous to the Automatic mode without the configuration
information being displayed.
The "Display messages for all dialogs" property allows system errors/mes‐
sages to be suppressed during execution.
Messages to be suppressed are acknowledged via automatic actuation of
the standard button.
All of the user-defined messages (Msg(), Input(), Warning(), Error(), etc.)
appear independently of this configuration. If these messages of the user are
also to be hidden, then the user must do this himself using corresponding
system variables.
Create MyConfig - Expert
4.4 Project folder
113