Table 206 SNMP Interface Traps (continued)
OPTION
OBJECT LABEL
transceiver-ddm
zyTransceiverDdmiTemperature
OutOfRange
zyTransceiverDdmiTxPowerOutO
fRange
zyTransceiverDdmiRxPowerOutO
fRange
zyTransceiverDdmiVoltageOutO
fRange
zyTransceiverDdmiTxBiasOutOfR
ange
zyTransceiverDdmiTemperature
OutOfRangeRecovered
zyTransceiverDdmiTxPowerOutO
fRangeRecovered
zyTransceiverDdmiRxPowerOutO
fRangeRecovered
zyTransceiverDdmiVoltageOutO
fRangeRecovered
zyTransceiverDdmiTxBiasOutOfR
angeRecovered
Storm-control
zyPortStormControlTrap
zuld
zyZuldUnidirectionalDetected
zyZuldBidirectionalRecovered
Chapter 45 Access Control
OBJECT ID
1.3.6.1.4.1.890.1.15.3.84.3.1
1.3.6.1.4.1.890.1.15.3.84.3.2
1.3.6.1.4.1.890.1.15.3.84.3.3
1.3.6.1.4.1.890.1.15.3.84.3.4
1.3.6.1.4.1.890.1.15.3.84.3.5
1.3.6.1.4.1.890.1.15.3.84.3.6
1.3.6.1.4.1.890.1.15.3.84.3.7
1.3.6.1.4.1.890.1.15.3.84.3.8
1.3.6.1.4.1.890.1.15.3.84.3.9
1.3.6.1.4.1.890.1.15.3.84.3.10
1.3.6.1.4.1.890.1.15.3.78.2.1
1.3.6.1.4.1.890.1.15.3.110.3.1
1.3.6.1.4.1.890.1.15.3.110.3.2
XGS2210 Series User's Guide
450
DESCRIPTION
This trap is sent when the transceiver
temperature is above or below the
normal operating range.
This trap is sent when the transmitted
optical power is above or below the
normal operating range.
This trap is sent when the received
optical power is above or below the
normal operating range.
This trap is sent when the transceiver
supply voltage is above or below the
normal operating range.
This trap is sent when the transmitter
laser bias current is above or below
the normal operating range.
This trap is sent when the transceiver
temperature is recovered from the
out of normal operating range.
This trap is sent when the transmitted
optical power is recovered from the
out of normal operating range.
This trap is sent when the received
optical power is recovered from the
out of normal operating range.
This trap is sent when the transceiver
supply voltage is recovered from the
out of normal operating range.
This trap is sent when the transmitter
laser bias current is recovered from
the out of normal operating range.
This trap is sent when storm control is
detected on a specific port. A packet
filter action has been applied on the
interface.
This trap is sent when a unidirectional
link is detected.
This trap is sent when the port which is
shut down by ZULD becomes active
again.