cpu_redundancy hello-interval

Command Mode
Description
Syntax
Sample Output
Systems
Document No. 10-300090, Issue 1
Global Configuration.
Sets the hello time in seconds for the standby supervisor. The valid range is
1 to 300 seconds. The default setting is 5 seconds. The no command
restores the default setting.
To Configure:
cpu_redundancy hello-interval <seconds>
To Disable:
no cpu_redundancy hello-interval
Table 30-28. Parameters, Keywords, Arguments
Name
Definition
<seconds>
Hello-time in seconds. The valid range is 1 to 300 seconds.
The default setting is 5 seconds.
The following example sets the hello time for the standby supervisor to 2
seconds.
(configure)# cpu_redundancy hello-interval 2
P550R, P580, P880, and P882.