Pressing the button "MODE" for less than 1 second displays the symbols in turn. The se-
lected symbol remains lit.
Pressing button "MODE" for longer than 3 seconds resets the kilometre reading for the
symbol selected, in "SERVICE" mode the date is also reset.
NOTE
AT THE MOMENT THE DATE IS RESET, THE "SERVICE" SYMBOL IS ACTIVATED
AGAIN.
PERFORM THE RESET PROCEDURE ONLY AT THE MOMENT OF DELIVERY OF THE
SCOOTER TO THE CUSTOMER IN ORDER THAT THIS SYMBOL SIGNALS THE NEED
FOR THE FIRST SERVICE IN RELATION TO THE DISTANCE TRAVELLED AND THE
TIME SINCE THE ACTIVATION.

Sealed battery

If the vehicle is provided with a sealed battery, the only maintenance required is the check of its charge
and recharging, if necessary.
These operations should be carried out before delivering the vehicle, and on a six-month basis while
the vehicle is stored in open circuit.
Besides upon pre-delivery it is therefore necessary to check the battery charge and recharge it, if re-
quired, before storing the vehicle and afterwards every six months.
INSTRUCTIONS FOR THE BATTERY REFRESH AFTER OPEN-CIRCUIT STORAGE
1) Voltage check
Before installing the battery on the vehicle, check the open circuit voltage with a standard tester.
- If voltage exceeds 12.60 V, the battery can be installed without any renewal recharge.
- If voltage is below 12.60 V, a renewal recharge is required as explained in 2).
2) Constant voltage battery charge mode
- Constant voltage charge equal to 14.40 to 14.70V
- Initial charge voltage equal to 0.3 to 0.5 for Nominal capacity
- Charge time:
10 to 12 h recommended
Minimum 6 h
Maximum 24 h
3) Constant current battery charge mode
- Charge current equal to 1/10 of the nominal capacity of the battery
- Charge time: 5 h
CAUTION
NEVER USE FUSES WITH A CAPACITY HIGHER THAN THAT RECOMMENDED. THE USE OF A
FUSE OF UNSUITABLE CAPACITY MAY RESULT IN SERIOUS DAMAGES TO THE WHOLE VE-
HICLE OR EVEN CAUSE A FIRE.
CHARGE THE BATTERY BEFORE USE TO ENSURE OPTIMUM PERFORMANCE. INADEQUATE
CHARGING OF THE BATTERY WITH A LOW ELECTROLYTE LEVEL BEFORE IT IS FIRST USED
SHORTENS THE LIFE OF THE BATTERY.
IF THE VEHICLE IS NOT USED FOR SOME TIME (1 MONTH OR MORE) THE BATTERY NEEDS
TO BE RECHARGED PERIODICALLY. THE BATTERY RUNS DOWN COMPLETELY IN THE
Electrical system