System Bleed - APRILIA SR MAX 125 ie Service Station Manual

Table of Contents

Advertisement

SR MAX 125 ie
Specification
Recommended fluid
Sealing pressure
Specification
Starts opening at
Specification
Electric ventilation starts at
Electric ventilation stops at
Specification
Control
Specification
Specification
Calibration

System bleed

- Start up the engine until the operating tempera-
ture is reached.
- Remove the rubber hood over the bleed valve
- Obtain a rubber tube that is of the right length to
connect the valve to the expansion tank
- Place one end of the pipe on the bleed valve and
the other in the expansion tank
- Loosen the screw by two turns until the commu-
nication hole is revealed with the head as shown
in the picture
- Wait until only coolant comes out of the rubber
pipe so as to eliminate any air bubbles inside the
circuit.
- Tighten the bleed valve respecting the maximum
torque.
- Bring the coolant up to the correct level inside the
expansion tank
Locking torques (N*m)
THERMOSTAT
Type
ELECTRIC VENTILATION
WATER PUMP
Type
RADIATOR
Type
EXPANSION TANK
Desc./Quantity
AGIP PERMANENT SPEZIAL (ready for use)
Cap calibrated at 0.9 bar
Desc./Quantity
Wax-type, with deviator
85 ± 2°C
Desc./Quantity
100° C
90° C
Desc./Quantity
Centrifugal
Electric, commanded by the control unit
Desc./Quantity
Aluminium, with horizontal circulation
Desc./Quantity
Automatic bleeding, in parallel with the radiator
Cooling system
COOL SYS - 247