APRILIA SR MAX 125 ie Service Station Manual page 137

Table of Contents

Advertisement

SR MAX 125 ie
- Reset the dial gauge.
- Unscrew the stop nut of the set screw.
- Using the dial gauge measure the residual stroke
value by undoing the set screw until the end of
stroke.
Characteristic
Residual stroke:
0.8 - 1.8 mm
- Check residual stroke by comparing it with the data contained in the next page.
RESIDUAL STROKE CHECK
- Check the residual stroke and afterwards make sure that it falls within the predetermined limits.
Characteristic
Residual stroke:
0.8 - 1.8 mm
Engine
ENG - 137