Figure 3‐1. Example of Typical Online Screen

Transducer Block Mode

Modes
The transducer block can be in one of two modes:
d Automatic (Auto)— This is the operational mode for this block. When the transducer block is in the Auto mode, all
other functions blocks will function normally.
d Out of Service (OOS)— Placing the transducer block in Out of Service mode changes the output to the zero power
(no I/P drive) condition.
Note
To setup and calibrate the instrument the transducer block mode must be in Auto and Write Locking (see page 26) must be Acyclic
Writeable.