Blocks—AI Function Block
June 2017
Table C‐8. Analog Input Block Parameter Definitions
Label
PARAMETER_NAME
High High Alarm
HI_HI_ALM
UNACKNOWLEDGED
ALARM_STATE
TIME_STAMP
SUBCODE
VALUE
High Alarm
HI_ALM
UNACKNOWLEDGED
ALARM_STATE
TIME_STAMP
SUBCODE
VALUE
Low Alarm
LO_ALM
UNACKNOWLEDGED
ALARM_STATE
TIME_STAMP
SUBCODE
VALUE
Low Low Alarm
LO_LO_ALM
UNACKNOWLEDGED
ALARM_STATE
TIME_STAMP
SUBCODE
Simulate
SIMULATE
SIMULATE_STATUS
SIMULATE_VALUE
SIMULATE_ENABLED
OUT_UNIT_TEXT
Reserved by PI
PV
VALUE
STATUS
LOW_CUT
118
Index
RO /
Write Block
Number
RW
Mode
30
RO
-
30.1
30.2
30.3
30.4
30.5
31
RO
-
31.1
31.2
31.3
31.4
31.5
32
RO
-
32.1
32.2
32.3
32.4
32.5
33
RO
-
33.1
33.2
33.3
33.4
34
RW
ALL
35
RW
ALL
36-44
45
RO
45.1
45.2
46
RW
ALL
Default
Range
Value
0
0
0
0
Disabled
Note: Uncertain -
Simulated value end
0
will be rejected by
device
0
0: Disabled
0
<>0: Enabled
-
Extended Parameter
0
0
Positive
0
Instruction Manual
Description
Data Type: DS‐39
Contains the state of the upper limit of an alarm and
the associated time stamp.
Data Type: DS‐39
Contains the state of the upper limit of a warning
and the associated time stamp.
Data Type: DS‐39
Contains the state of the lower limit of a warning
and the associated time stamp.
Data Type: DS‐39
Contains the state of the lower limit of an alarm and
the associated time stamp.
Data Type: DS‐50
For commissioning and test purposes the input
value from the Transducer Block into the Analog
Input Function Block can be modified. This means
that the Transducer Block and Analog Input
Function Block will be disconnected.
Data Type: OctetString
If a specific unit of OUT parameter is not in the
code list you have the possibility to write the
specific text into this parameter. The unit code is
then equal to "textual unit definition".
Data Type: 101
Process Variable used in the process control.
Data Type: Float
This parameter is updated as long as the block
mode is not in OOS.
Data Type: Unsigned8
Indicates validity of VALUE.
Data Type: Float
If calculated output is below this value the
output is 0.
D103563X012