Fisher FIELDVUE DVC6200p Instruction Manual page 117

Digital valve controller
Hide thumbs Also See for FIELDVUE DVC6200p:
Table of Contents

Advertisement

Instruction Manual
D103563X012
Table C‐8. Analog Input Block Parameter Definitions
Label
PARAMETER_NAME
PROFILE_REVISION
EXECUTION_TIME
NUMBER_OF_PARAMETERS
ADDRESS_OF_VIEW_1
NUMBER_OF_VIEWS
Static Revision
ST_REV
Tag Description
TAG_DESC
Strategy
STRATEGY
Alert Key
ALERT_KEY
TARGET MODE
Block Mode
MODE_BLK
ACTUAL
PERMITTED
NORMAL
Alarm Summary
ALARM_SUM
CURRENT
UNACKNOWLEDGED
UNREPORTED
DISABLED
Index
RO /
Write Block
Number
RW
Mode
0.9
0.10
0.11
0.12
0.13
1
RO
2
RW
ALL
3
RW
ALL
4
RW
ALL
5
RW
ALL
6
RO
6.1
6.2
6.3
7
RO
7.1
7.2
7.3
7.4
Default
Range
Value
Octet 1:
Number before the
decimal point.
0x0302
Octet 2:
Number after the
decimal point.
0
0x2F
Octet 1:
(MSB): Slot.
Octet 2:
0x023F
(LSB): Index of View_1
parameter for access
0x01
0 to 65535
0
Null
0
0 to 255
0
Bit 7: OOS
Bit 4: Man
OOS
Bit 3: Auto
Bit 7: OOS
Bit 4: Man
Bit 3: Auto
N/A
OOS + MAN +
OOS + MAN + AUTO
AUTO
AUTO
Octet 1:
Bit 0: Reserved
Bit 1: HI_HI_Alarm
Bit 2: HI_Alarm
Bit 3: LO_LO_Alarm
Bit 4: LO_Alarm
Bits 5 - 6: Reserved
Bit 7: Update Event -
Set after any STATIC
parameter is changed.
Octet 2:
Reserved
0
0
0
0
Blocks—AI Function Block
Description
Data Type: Unsigned16
Profile revision used for this device.
Data Type: Unsigned8
Data Type: Unsigned16
Number of used parameters in the block.
Data Type: Unsigned16
Address of View 1 parameter, see table C‐9.
Data Type: Unsigned8
Number of view objects of the block.
Data Type: Unsigned16
The revision level of the static data. Increments by
one each time a static parameter changes, or a
change of a table is accepted. Reset to 0 in case of a
cold start (ie if FACTORY_RESET = 1 is set). Set to 1 if
overflow.
Data Type: Octet String
The user description of the intended application of
the block.
Data Type: Unsigned16
User-specified value used in configuration or
diagnostics as a key in sorting block information.
Data Type: Unsigned8
The identification number of the plant unit. This
information may be used in the host for sorting
alarms or events generated by blocks.
Data Type: Unsigned8
Target mode of the block.
Data Type: DS‐69
Valid Bits: 7: OOS, 4: MAN, 3: AUTO
The actual, permitted, and normal modes of the
block.
Actual: The current mode of the block
Permitted: Allowed modes for TARGET_MODE.
Normal: Desired operating mode.
Data Type: DS‐42
Current alert status, unacknowledged states,
unreported states, and disabled states of the
alarms associated with the function block.
Date Type: Octet String
Current active alerts. Limit alarm bits are cleared
when the alarm condition is cleared. Update event
bit is cleared after 20s (condensed status) or 10s
(classic status).
Not used
Not used
Not used
June 2017
115