NOTE:
Each power supply must be connected to a dedicated power source
outlet.
To install an AC power supply in the switch:
Ensure that you have the correct power supply. The label
1.
(AFO)
on the power supply must match the label
the installed fan module.
Attach the ESD grounding strap to your bare wrist, and connect the strap to the ESD
2.
point on the chassis.
If the power supply slot has a cover panel on it, loosen the captive screws on the cover
3.
panel by using your fingers or a screwdriver. Hold the captive screw and gently pull it
outward to remove the cover panel. Save the cover panel for later use.
Taking care not to touch power supply pins, leads, or solder connections, remove the
4.
power supply from the bag.
Using both hands, place the power supply in the power supply slot on the rear panel
5.
of the switch and slide it in until it is fully seated and the clip clicks into place. See
Figure 24 on page
78.

Figure 24: Installing an AC Power Supply in an OCX1100-48SX Switch

NOTE:
If you have a Juniper J-Care service contract, register any addition,
change, or upgrade of hardware components at
https://www.juniper.net/customers/support/tools/updateinstallbase/
to do so can result in significant delays if you need replacement parts. This
note does not apply if you replace existing components with the same type
of component.
Removing an AC Power Supply from an OCX1100 Switch on page 111