Removing a Fan Module from an OCX1100 Switch

106
Remove the fan module from its bag.
3.
Hold the handle of the fan module with one hand and support the weight of the module
4.
with the other hand. Place the fan module in the fan module slot on the rear panel of
the switch and slide it in until it is fully seated and the clip clicks into place. See
Figure 34 on page 106
Figure 34: Installing a Fan Module in an OCX1100–48SX Switch
NOTE:
If you have a Juniper J-Care service contract, register any addition,
change, or upgrade of hardware components at
https://www.juniper.net/customers/support/tools/updateinstallbase/
to do so can result in significant delays if you need replacement parts. This
note does not apply if you replace existing components with the same type
of component.
Removing a Fan Module from an OCX1100 Switch on page 106
Cooling System and Airflow in an OCX1100 Switches on page 17
Field-Replaceable Units in OCX1100 Switches on page 12
OCX1100 Switches Hardware Overview on page 3
The fan module in OCX1100 switches is a hot-removable and hot-insertable
field-replaceable unit (FRU) installed in the rear panel of the switch: You can remove
and replace it without powering off the switch or disrupting switch functions.
Ensure that you have the following parts and tools available:
Phillips (+) screwdriver
An antistatic bag or an antistatic mat
A replacement fan module
. Failure