OCX1100 Switch Hardware Guide

Table 12: Fan Modules in OCX1100-48SX Switches

Fan Module
OCX-FAN-X-AFO
OCX-FAN-X-AFI

Airflow Direction in OCX1100-48SX Switch Models

Table 13: Airflow Direction in OCX1100-48SX Switch Models

Model Number
OCX1100-48SX-AFO
18

Figure 9: Fan Module Used in an OCX1100 Switch

CAUTION:
You must remove only one fan module at a time for replacement
from the rear panel of the chassis. The switch continues to operate without
thermal shutdown for a limited period of time (30 seconds) during the
replacement of a fan module.
NOTE:
Four fan modules must be installed for optimal functioning of the
switch.
The fan modules are available in two models that have different airflow
directions—back-to-front (air enters through the vents on the rear panel of the switch
chassis), indicated by the label
vents on the rear panel of the switch chassis), indicated by the label
Table 12 on page 18
lists the available fan module models and the direction of airflow in
them.
Table 13 on page 18
shows the direction of airflow in OCX1100-48SX switch models as
shipped.
Fan Modules and Power Supply
The switch ships with four fan modules and
two AC power supplies installed; all bearing
the label

AIR OUT (AFO)

.
AIR IN (AFI)
, and front-to-back (air exhausts through the
Label on the Fan Module
AIR OUT (AFO)
AIR IN (AFI)
Direction of Airflow
Front-to-back—that is, air intake to cool the
chassis is through the vents on the front panel
of the chassis and hot air exhausts through
the vents on the rear panel of the chassis.