Download Print this page

Juniper OCX1100 Hardware Manual page 28

Advertisement

OCX1100 Switch Hardware Guide
Table 5: CLI Equivalents of Terms Used in the Documentation for OCX1100-48SX
Switches (continued)
Hardware
Item (CLI)
Description (CLI)
Routing
One of the following:
Engine (n)
OCX1100-48SX-AFO
OCX1100-48SX-AFI
OCX1100-48SX-D-AFO
OCX1100-48SX-D-AFI
FPC (n)
Abbreviated name of
the Flexible PIC
Concentrator (FPC)
One of the following:
OCX1100-48SX-AFO
OCX1100-48SX-AFI
OCX1100-48SX-D-AFO
OCX1100-48SX-D-AFI
PIC (n)
Abbreviated name of
the Physical Interface
Card (PIC)
48x10G-6x40G
Xcvr (n)
Abbreviated name of
the transceiver
Power supply
One of the following:
(n)
OCX-460W-X-AC-AFI
OCX-460W-X-AC-AFO
OCX-800W-X-DC-AFI
OCX-800W-X-DC-AFO
8
Value
Item In Documentation
Value of n is always 0.
RE refers to the switch
itself.
Value of n is always 0.
The switch does not have
actual FPCs. In this case,
FPC refers to the switch
itself.
Value of n is always 0.
PIC 0
PIC 0 stands for the
built-in SFP+ and QSFP+
ports. In the CLI output,
the SFP+ ports are
numbered 1 through 48
and the QSFP+ ports are
numbered 49 through 54.
n is a value equivalent to
Optical transceivers
the number of the port in
which the transceiver is
installed.
Value of n is always 0.
AC power supply or DC
power supply
CAUTION:
Do not install:
AC and DC power supplies in the same chassis.
AC power supplies in DC switch models or DC power supplies in AC switch models.
Power supplies with different airflow labels (
the same chassis.
Power supplies and fan modules with different airflow labels (
) in the same chassis.
OUT (AFO)
Additional Information
"OCX1100 Switches
Hardware Overview" on
page 3
"Pluggable Transceivers
Supported on OCX1100
Switches" on page 47
AC Power Supply in
OCX1100 Switches on
page 23
DC Power Supply in
OCX1100 Switches on
page 25
AIR IN (AFI)
and
AIR OUT (AFO)
AIR IN (AFI)
and
Copyright © 2017, Juniper Networks, Inc.
) in
AIR

Advertisement