Common Alarming - Avaya 1110 Fundamentals

Communication server 1000
Hide thumbs Also See for 1110:
Table of Contents

Advertisement

Monitor
Message
queue
IP traffic
rate

Common alarming

The UNIStim firmware currently does not support alarming mechanism through standard
SNMP protocol. The feature function is to raise alarms to the server when Warning and Critical
events occur and to clear the alarms when phone back to normal; so that, the phone status
IP Deskphones Fundamentals
Threshol
d
Critical
Task stack monitor detects a
stack overflow (margin less than
0%.
Normal
Queue margin is calculated
more than 10% of its size.
Warning
Queue monitor detects a
message queue margin less
than 10% and more than 0% of
its size.
Critical
Queue monitor detects a queue
overflow (margin less than 0%).
Normal
Traffic rate is checked to be
lower than 90% of the defined
high threshold (for broadcast:
150 packets/ 100ms; for
multicast: 150 packets/100ms;
for Unicast: 150 packets/100ms)
when the port Rx is on.
Warning
Traffic rate is monitored higher
than or equal to 90% and lower
than 100% of the defined high
threshold (for broadcast: 150
packets/ 100ms; for multicast:
150 packets/100ms; for Unicast:
150 packets/100ms) when the
port Rx is on.
Critical
Traffic rate monitored reaches
the defined high threshold (for
broadcast: 150 packets/ 100ms;
for multicast: 150 packets/
100ms; for Unicast: 150 packets/
100ms) or the port Rx is off.
Usage
Log Major event and send
Critical alarming UNIStim
message and suspend the
suspicious task.
No action is required.
Log warning event and send
Warning alarming UNIStim
message.
Log Major event and send
Critical alarming UNIStim
message and suspend the
suspicious task.
No action is required.
Log warning event and send
Warning alarming UNIStim
message.
Log Major event and turn off the
port Rx for hold-off time (100
ms). Send a Critical alarming
UNIStim message.
Introduction
Action
February 2013
551

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents