Checking The Relays - Yamaha FZ-16 Service Manual

Hide thumbs Also See for FZ-16:
Table of Contents

Advertisement

Charging method with a charging voltage
constant
a.
Measuring open circuit voltage before
upload.
NOTE:
The voltage must be measured after 30 minutes
without using the battery.
b.
Connect a charger and an ammeter to
battery and start charging.
c.
Make sure the power is higher
than the standard load current
written in the battery.
NOTE:
If the load current is below the level of
written on the battery charge, this type of charger
battery can not charge the MF battery. It
recommends a variable voltage charger.
d.
Charge the battery until the charging voltage
battery is 15 V.
NOTE:
Adjust the charging time to 20 hours (maximum).
e.
Measuring the charging voltage in open circuit
battery, after having been without
use for more than 30 minutes.
12.8 V or more --- Charging complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
6.
Install:
Battery
7.
Connect:
Battery cables
(To the terminals of the battery)
CAUTION
First, connect the positive battery
"1", then the negative cable from the battery "2".
1
ELECTRICAL COMPONENTS
8.
Check:
Battery terminals
Sulfation→Clean with hot water.
Connect loose connection correctly.
9.
Lubricate:
Battery terminals
10.Instalar:
Seat and right side cover
Refer to "GENERAL CHASSIS"
on page 4-1.

CHECKING THE RELAYS

Check continuity of each switch
pocket tester. If the reading of continuity
is incorrect, replace the relay.
1.
Disconnect the relay set of wires
harness.
2.
Connect the multimeter (Ù × 1) and the terminal
battery (12 V) to relay terminal as
shows. Check the operation of the relay.
Replace out of specification.
Start relay
1. Positive battery terminal
2. Negative battery terminal
3. Tester positive probe
4. Tester negative probe
2
1
7-37
Recommended lubricant
Dielectric grease
Multimeter
1
2
3
R
B
R / W
LW
Result
Continuity
(Between "3" and "4")
4