Yamaha FZ-16 Service Manual page 249

Hide thumbs Also See for FZ-16:
Table of Contents

Advertisement

Check continuity of each circuit with the multimeter. If the reading of continuity is not
correct, check the connections, and if necessary, replace the switch.
CAUTION:
Never insert the tester probes into the slots of the coupling terminal "a".
Insert the probes provided by the opposite end of the coupler, taking care not
loosen or damage the cables.
Multimeter
NOTE:
• Before checking for continuity, set the multimeter in continuity mode.
l
• When checking the continuity, toggle switch positions several times.
Switches and terminal connections are illustrated in the following example of the
main switches.
The "a" are shown in the left column and the switch lead colors
"B" are shown in the top row.
Continuity (ie, a closed circuit) between switch terminals is given by the position
. "There is continuity between the red and brown / blue when the switch is indicated Estaque!
"ON".
ELECTRICAL COMPONENTS
b
R Br
ON
to
OFF
R
Br
7-32