Test the Alarm and Optional
Flashing Beacon
An alarm and optional flashing beacon are installed
to alert operators and ground personnel of
machine proximity and motion. There are four
alarm option modes that can be activated based on
user preference or requirement. Refer to Display
Module in the Repair Section for information.
1 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both the ground and platform
controls.
Result: The alarm should sound twice. The
flashing beacon (if equipped) should be on and
flashing.
Part No. 88619
Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
B-18

Perform Hydraulic Oil Analysis

Replacement or testing of the hydraulic oil is
essential for good machine performance and
service life. Dirty oil and a clogged suction strainer
may cause the machine to perform poorly and
continued use may cause component damage.
Extremely dirty conditions may require oil changes
to be performed more often.
Note: Before replacing the hydraulic oil, the oil may
be tested by an oil distributor for specific levels of
contamination to verify that changing the oil is
necessary. If the hydraulic oil is not replaced at
the two year inspection, test the oil quarterly.
Replace the oil when it fails the test.
See E-1, Test or Replace the Hydraulic Oil.