Test The Alarm Package (If Equipped) - Genie Z-34/22 Service Manual

Bi-energy power
Hide thumbs Also See for Z-34/22:
Table of Contents

Advertisement

April 2016
B-15
Test the Alarm Package (if
equipped)
Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
The alarm package includes:
• Travel alarm
• Descent alarm
• Flashing beacon
Alarms and a beacon are installed to alert
operators and ground personnel of machine
proximity and motion. The alarm package is
installed on the turntable covers.
Note: The alarms and beacon will operate with the
engine running or not running.
1
Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
Result: The flashing beacon should be on and
flashing.
2
Move the function enable switch to either side
and activate the primary boom toggle switch in
the down position, hold for a moment and then
release it.
Result: The descent alarm should sound when
the switch is held down.
3
Move the function enable switch to either side
and activate the secondary boom toggle
switch in the down position, hold for a moment
and then release it.
Result: The descent alarm should sound when
the switch is held down.
Part No. 139234
Checklist B Procedures
4
Move the function enable toggle switch to
either side and activate the jib boom toggle
switch in the down position, hold for a moment
and then release it.
Result: The descent alarm should sound when
the switch is held down.
5
Turn the key switch to platform controls.
Result: The flashing beacon should be on and
flashing.
6
Press down the foot switch. Activate the
primary boom toggle switch in the down
position, hold for a moment and then release
it.
Result: The descent alarm should sound when
the control handle is held down.
7
Press down the foot switch. Activate the
secondary boom toggle switch in the down
position, hold for a moment and then release
it.
Result: The descent alarm should sound when
the control handle is held down.
8
Press down the foot switch. Activate the jib
boom toggle switch in the down position, hold
for a moment and then release it.
Result: The descent alarm should sound when
the switch is held down.
9
Press down the foot switch. Move the drive
control handle off center, hold for a moment
and then release it. Move the drive control
handle off center in the opposite direction,
hold for a moment and then release it.
10 Result: The travel alarm should sound when
the drive control handle is moved off center in
either direction.
Z-34/22 Bi-Energy
Service Manual
37