Section 4 • Repair Procedures
GROUND CONTROLS
4 Using auxiliary power, operate the platform
level toggle switch to level the platform.
Note: Only the auxiliary power unit can be used to
correct an out of level platform fault.
5 Turn the service bypass/recovery key switch to
the run position.
6 Remove the key from the service bypass/
recovery key switch and insert the key into the
main key switch.
Note: If the Service Bypass function has been
used, there may be faults with the machine. Check
the LCD screen on the ground control box for
machine faults, then contact trained service
personnel.
How to Use the Recovery Mode
Recovery is only to be used as a last attempt to
lower the platform when the operator in the
platform is unable to do so, system failure or in
emergency situations.
Bodily injury hazard. When using
recovery mode, the platform may
not fully lower to the ground when
the recovery mode is completed.
Failure to use only suitable
equipment and/or practices to
allow the operator to safely exit
the platform could result in death
or serious injury.
Bodily injury hazard. Platform
leveling is not active when using
recovery mode. The platform
could reach high out-of-level
conditions when using this mode.
The operator will need to secure
themself to the platform to prevent
falling injury.
4 - 58
The Recovery mode allows the platform to be
lowered in the event the operator in the platform is
unable to lower the platform using the platform
controls, system failure or emergency situations.
The recovery sequence will automatically retract
the primary boom and then lower the primary boom
using the auxiliary power unit to allow the operator
at the platform controls to exit the platform.
1 Turn the main key switch to the off position.
Remove the key from the main key switch and
insert the key into the service bypass/recovery
key switch.
2 Turn and hold the service bypass/recovery key
switch to the recovery position. The switch must
be held in the recovery position.
Result: The auxiliary power unit will turn on and
the boom will begin the following recovery
sequence.
· The primary boom will retract
· The primary boom will lower
Note: The key switch must be held in the recovery
position until the recovery sequence is complete or
until the operator in the platform can safely exit the
platform.
Note: If any boom safety limit switches are faulty,
the boom will only retract and not lower and the
operator will need to be recovered from that point.
Note: If the Recovery function has been used, this
may indicate there may be faults with the machine.
Tag and remove the machine from service until the
fault has been corrected by trained personnel.