Section 3 • Scheduled Maintenance Procedures
CHECKLIST E PROCEDURES
15 Install the suction strainers using a thread
sealant on the threads.
16 Install the drain plug using a thread sealant on
the threads.
17 Install the hydraulic return filter housing onto the
hydraulic tank.
18 Install the hydraulic tank onto the machine.
19 Install the two suction hoses to the suction
strainers.
20 Install the supply hose for the auxiliary power
unit and the return filter hose.
Models with hydraulic tank shut-off valves:
21 Open the two hydraulic tank valves at the
hydraulic tank.
22 Fill the tank with hydraulic oil until the level is
within the top 2 inches / 5 cm of the sight
gauge. Do not overfill.
23 Clean up any oil that may have spilled.
3 - 62
24 Prime the pump. Refer to Repair Procedure
7-2, How to Prime the Pump.
Note: Always use pipe thread sealant when
installing the suction hose fittings and the drain
plug.
Component damage hazard. The
engine must not be started with
the hydraulic tank shut-off valves
in the closed position or
component damage will occur. If
the tank valves are closed,
remove the key from the key
switch and tag the machine to
inform personnel of the condition.