B-12
Test the Alarm Package
(If Equipped)
The alarm package includes:
· Travel alarm
· Descent alarm
· Flashing beacon
Alarms and a beacon are installed to alert
operators and ground personnel of machine
proximity and motion. The flashing beacon is
installed on the lower leveling arm and the descent
and travel alarms are installed on the rear of the
machine above the hydraulic component tray.
1 Turn the key switch to ground control and pull
out the Emergency Stop button to the
position at both the ground and platform
controls.
Result: The flashing beacon should be on and
flashing.
2 Move the boom toggle switch to the
position, hold for a moment and then release it.
Result: The descent alarm should sound when
the switch is held down.
3 Turn the key switch to platform control.
4 Move the lift/drive select switch (if equipped) to
the lift position.
4 - 18
ON
DOWN
Genie Z-20/8N & Genie Z-20/8 & Genie Z-25/8
5 Press down the foot switch.
Result: The flashing beacon should be on
and flashing.
6 Press down the foot switch. Move the boom
toggle switch to the
moment and then release it.
Result: The descent alarm should sound when
the switch is held down.
7 Move the lift/drive select switch (if equipped) to
the drive position.
8 Press down the foot switch.
9 Move the drive control handle off center, hold
for a moment and then release it. Move the
drive control handle off center in the opposite
direction, hold for a moment and then release it.
Result: The travel alarm should sound when the
drive control handle is moved off center in
either direction.