June 2011
REV B
Code
Problem
Megajector internal
363
actuator fault detection
Megajector internal circuitry
364
fault detection
MegaJector internal
365
communication fault
detection
411
Coil Driver #1 Open
412
Coil Driver #1 Shorted
413
Coil Driver #2 Open
414
Coil Driver #2 Shorted
511
FPP1 High Voltage
512
FPP1 Low Voltage
513
FPP1 Higher than IVS Limit
514
FPP1 Lower than IVS Limit
521
FPP2 High Voltage
522
FPP2 Low Voltage
531
TPS1 (Signal Voltage) High
532
TPS1 (Signal Voltage) Low
533
TPS2 (Signal Voltage) High
534
TPS2 (Signal Voltage) Low
Megajector internal
363
actuator fault detection
Part No. 88619
Cause
The MegaJector detects an internal fault. Open or
short in power, ground or CAN circuits.s
The MegaJector detects an internal circuitry
failure. Open or short in power, ground or CAN
circuits.
The MegaJector detects an internal
communications failure. Open or short in power,
ground or CAN circuits.
Open wiring and/or connections to ignition coil #1
OR ignition coil #1 is faulty.
Wiring and/or connections to ignition coil #1
shorted OR ignition coil #1 is faulty.
Open wiring and/or connections to ignition coil #2
OR ignition coil #2 is faulty.
Wiring and/or connections to ignition coil #2
shorted OR ignition coil #2 is faulty.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
The #1 throttle position sensor wiring and/or
connections open or shorted OR there is a poor
system ground connection OR throttle position
sensor #1 is faulty.
The #1 throttle position sensor wiring and/or
connections open or shorted OR there is a poor
system ground connection OR throttle position
sensor #1 is faulty.
The #2 throttle position sensor wiring and/or
connections open or shorted OR there is a poor
system ground connection OR throttle position
sensor #2 is faulty.
The #2 throttle position sensor wiring and/or
connections open or shorted OR there is a poor
system ground connection OR throttle position
sensor #2 is faulty.
The MegaJector detects an internal fault. Open or
short in power, ground or CAN circuits.s
Z-80/60
Section 5 • Fault Codes
FORD ECM FAULT CODE CHART
Solution
Check Power, Ground and CAN circuits at
MegaJector and all connections and repair
as necessary OR MegaJector has an
internal fault. Contact Ford Power Products
for assistance.
Check Power, Ground and CAN circuits at
MegaJector and all connections and repair
as necessary OR MegaJector has an
internal fault. Contact Ford Power Products
for assistance.
Check Power, Ground and CAN circuits at
MegaJector and all connections and repair
as necessary OR MegaJector has an
internal fault. Contact Ford Power Products
for assistance.
Repair wiring and/or connections to ignition
coil #1 OR replace ignition coil #1.
Repair wiring and/or connections to ignition
coil #1 OR replace ignition coil #1.
Repair wiring and/or connections to ignition
coil #1 OR replace ignition coil #1.
Repair wiring and/or connections to ignition
coil #2 OR replace ignition coil #2.
If this fault appears on your machine, contact
Genie Industries Service Department.
If this fault appears on your machine, contact
Genie Industries Service Department.
If this fault appears on your machine, contact
Genie Industries Service Department.
If this fault appears on your machine, contact
Genie Industries Service Department.
If this fault appears on your machine, contact
Genie Industries Service Department.
If this fault appears on your machine, contact
Genie Industries Service Department.
Be sure system ground connections are in
place and secure OR repair wiring and/or
connections to sensor OR replace throttle
position sensor #1.
Be sure system ground connections are in
place and secure OR repair wiring and/or
connections to sensor OR replace throttle
position sensor #1.
Be sure system ground connections are in
place and secure OR repair wiring and/or
connections to sensor OR replace throttle
position sensor #2.
Be sure system ground connections are in
place and secure OR repair wiring and/or
connections to sensor OR replace throttle
position sensor #2.
Check Power, Ground and CAN circuits at
MegaJector and all connections and repair
as necessary OR MegaJector has an
internal fault. Contact Ford Power Products
for assistance.
Continued on next
page