Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
10 Check the ambient air temperature and adjust
the specific gravity reading for each cell as
follows:
• Add 0.004 to the reading of each cell for
every 10° / 5.5° C above 80° F / 26.7° C.
• Subtract 0.004 from the reading of each cell for
every 10° / 5.5° C below 80° F / 26.7° C.
Result: All battery cells display a specific gravity
of 1.277 or greater. The battery is fully charged.
Proceed to step 13.
Result: The difference in specific gravity
readings between cells is greater than 0.1 OR
the specific gravity of one or more cells is less
than 1.177. Replace the battery.
11 Check the battery acid level. If needed,
replenish with distilled water to
below the bottom of the battery fill tube. Do not
overfill.
12 Install the vent caps and neutralize any
electrolyte that may have spilled.
3 - 20
B-2

Inspect the Electrical Wiring

Maintaining electrical wiring in good condition is
essential to safe operation and good machine
performance. Failure to find and replace burnt,
chafed, corroded or pinched wires could result in
unsafe operating conditions and may cause
component damage.
1 Open the engine side turntable cover.
1
/
inch / 3 mm
8
2 Remove the engine tray retaining fastener.
3 Locate the engine tray anchor hole at the pivot
Z-80/60
Electrocution hazard. Contact with
hot or live circuits could result in
death or serious injury. Remove all
rings, watches and other jewelry.
Swing the engine tray out away from the
machine.
a
engine tray anchor hole
b
engine tray retaining fastener
end of the engine tray.