Port Configuration - Samsung WEC8500 Operation Manual

Wireless enterprise access point controller
Hide thumbs Also See for WEC8500:
Table of Contents

Advertisement

CHAPTER 3.
In this chapter, how to set up the data network functions of APC including VLAN, link
aggregation, and layer 3 protocol is described.
3.1

Port Configuration

The APC port is configured with a physical interface.
Physical interface of 11 ports except WEC8500 console port
Physical interface of 4 ports except WEC8050 console port
3.1.1
Port management
The WEC8500 Management port is used to manage the WEC8500. It does not
support VLAN and its interface name is 'mgmt0'. The 8 ports at the right side of
Management port are 10/100/1000 BASE T-ports and their names are GE1-8.
To the right side of the 10/100/1000 BASE T-ports, there are two Gigabit ports, i.e.
XE1 and XE2. In case of WEC8050, there is no management (mgmt0) port,
connect the Ethernet cable to the port in one of ports ge1 to ge4,
Configuration using CLI
To configure the port related function, enter into the interface mode by entering the
'interface [INTERFACE_NAME]' command in the configure mode.
An example of entering into the interface setup mode of the management port is shown
below.
WEC8500# configure terminal
WEC8500/configure# interface mgmt0
WEC8500/configure/interface mgmt0#
© SAMSUNG Electronics Co., Ltd.
Data Network Function
CHAPTER 3. Data Network Function
page 61 of 689

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wec8050

Table of Contents