Configuration using Web UI
In the menu bar of <WEC Main window>, select <CONFIGURATION> and then select
the <RADIO> <802.11a/n> or <802.11b/g/n> <Admission Control> menu in the
sub-menus.
After configuring the below item in the Call Admission Control, click the <Apply> button.
ADMISSION CONTROL: Configures the CAC function.
MAX CALLS: Maximum number of allowed calls (range: 2-30)
HANDOVER CALLS: Number of marginal calls considering handover (range: 0-10)
The number of allowed calls is MAX CALLS-HANDOVER CALLS.
MINOR ALARM THRESHOLD: Configures a threshold that generates a Minor alarm
(range: 0-15)
Enter '0' to prevent the alarm.
MAJOR ALARM THRESHOLD: Configures a threshold that generates a Major alarm
(range: 0-30)
Enter '0' to prevent the alarm.
© SAMSUNG Electronics Co., Ltd.
Figure 176. Admission control configuration
CHAPTER 7. WLAN Additional Services
page 314 of 689