Stretching The Scanner Wire - Konica Minolta BIZHUB 501 Service Manual

Hide thumbs Also See for BIZHUB 501:
Table of Contents

Advertisement

6. OTHERS
6.3.17

Stretching the scanner wire

Note
• Be sure to wind the scanner wire around the pulley closely with no scanner wire overlapping each
other.
• When restretching or replacing the scanner wire, be sure to use the optics unit positioning jig.
• When restretching or replacing the scanner wire, be sure to conduct the image adjustment in the
service mode. (See P.182, P.183, P.184, P.185, P.186, P.187)
A. Procedure
[4]
[3]
[6]
[1]
[2]
154
[5]
[4]
[1]
[2]
a0r5f2c019ca
[3]
a0r5f2c020ca
Field Service Ver.2.0 Mar. 2009
1.
Remove the original glass. At this time, remove
also the glass attaching plate /Lw.
(See P.141)
2.
Remove the upper covers /Fr and /Lt.
(See P.143)
3.
Remove the upper cover /Rr.
(See P.144)
4.
Remove six screws [1] and remove the wiring har-
ness cover [2].
5.
Remove the wiring harness [3] from the wiring
harness clamp.
6.
Remove five screws [4] and remove the right side
plate of the scanner [5].
Note
• When removing the right side plate of the
scanner [5], change the direction of the oper-
ation panel and loosen the wiring harness [6].
7.
Move the V-mirror unit [1] to the vicinity of the V-
mirror positioning hole [2].
8.
Insert the optics unit positioning jig [3] into the V-
mirror positioning hole and fix the V-mirror unit.
Note
• Be sure to insert the optics unit positioning jig
[3] from the operation panel side and pass it
through the V-mirror unit.