Konica Minolta BIZHUB 501 Service Manual page 165

Hide thumbs Also See for BIZHUB 501:
Table of Contents

Advertisement

6. OTHERS
B. Mirror unit/exposure unit
(1) Positions not allowed to be adjusted
Positions at which the mirror unit and the exposure unit are installed
[1]
Mirror unit
(2) Reason for prohibition
The distance between the mirror unit and the exposure unit has an effect on the magnification in the sub scan
direction of the original to be read. Accordingly, the positions at which the mirror unit and the exposure unit are
installed must not be arbitrarily adjusted. However, when removing the exposure unit and the scanner wire, the
adjustments can be made only if they are reinstalled by using the optics unit positioning jig.
128
[2]
Field Service Ver.2.0 Mar. 2009
[1]
[2]
Exposure unit
50gaf2c137na