10. SERVICE MODE
*27 Fusing temperature setting while in the selection
of thin paper
When there occurs a problem (insufficient fusing) with
fusibility while in the selection of thin paper, change
the fusing set temperature. (For countermeasure, see
*25.)
*28 Fusing temperature setting while in the selection
of OHP
When there occurs a problem (insufficient fusibility
and large paper curl) with fusibility while in the selec-
tion of OHP, change the fusing set temperature. (For
countermeasure, see *25.)
*29 Switchover of the original glass and the ADF size
detection
This setting is to support the originals of other than
the standard size.
*30 Size conversion of A4 /8
glass is small size.
This setting is to convert the size conversion of the
small originals which are detectable.
Note
• The size conversion of the small size originals which
are undetectable can be set with Dipsw21-5.
*31 Operation at setting paper onto the bypass feed
tray
Set the operation when setting paper onto the
bypass feed tray.)
288
1
/
x 11 when the original
1
2
Field Service Ver.2.0 Mar. 2009
Mode
Standard
Standard + 10 °C
Mode
Standard
Standard + 10 °C
Standard – 20 °C
Standard – 10 °C
Mode
No setting
Size detection setting of
8
/
x 13
/
1
1
2
2
(for Hong-Kong area)
Detection setting of
8
/
x 14
1
2
(for Europe area)
Setting is prohibited
Mode
Invalid
Valid
Mode
Reset size with selecting
the bypass feed tray
Does not reset size with
selecting the bypass feed
tray
Reset size without select-
ing the bypass feed tray
Reset size without select-
ing the bypass feed tray
36-5
0
1
36-7
36-6
0
0
0
1
1
0
1
1
37-4
37-3
0
0
0
1
1
0
37-5
0
1
38-4
38-3
0
0
0
1
1
0
1
1