Field Service Ver.2.0 Mar. 2009
[5]
[4]
[1]
[3]
[1]
[2]
[1]
[3]
50gaf2c134na
[2]
50gaf2c135na
9.
Remove the 2 C-rings [1] and pull out the shaft [2].
10.
Remove the separation roller mounting plate [3].
Note
• When removing the separation roller mount-
ing plate, be careful that the spring [4] does
not get lost since it is apt to come off.
• When installing the separation roller mount-
ing plate, be sure to install it so that it comes
under the projection [5].
11.
Remove the guide [1].
12.
Remove the C-ring [2] and then remove the sepa-
ration roller assy [3].
13.
Reinstall the above parts following the removal
steps in reverse.