Adjusting The Needle Thread Clamp Sensor - JUKI AMS-210E Series Engineer's Manual

Hide thumbs Also See for AMS-210E Series:
Table of Contents

Advertisement

(41) Adjusting the needle thread clamp sensor

When the needle thread clamp support plate complete
clamp position (Caution 1., 2.) the clearance A toward the needle thread clamp
(Caution) 1. The needle thread clamp position is known as the position returned by one step from the
most advanced position when the
Mode I08 (IP-400) or CP-7 (CP-20).
2. According to the thread clamp specifications, the memory switch U69 may change.
S Type → → → → → 0
H Type → → → → → 1
A
Standard Adjustment
is withdrawn by 3 to 4 pulses from the needle thread
key is pressed after the origin retrieval by the Test
3 to 4mm
– 63 –
becomes 0.
B
C