JUKI AMS-210E Series Engineer's Manual page 207

Hide thumbs Also See for AMS-210E Series:
Table of Contents

Advertisement

Error code
E438
E441
E703
E704
E730
E731
E733
E802
E811
E813
E901
Pict
Execution cannot be performed.
Back-up data does not exist.
Panel is connected to the machine other than
supposed. (Machine type error)
When machine type code of system is improper in
case of initial communication.
Inconsistency of system version
When version of system software is improper in
case of initial communication.
Main shaft motor encoder defectiveness or
phase-out
When encoder of sewing machine motor is
abnormal.
Main motor hole sensor defectiveness or
position sensor defectiveness
When hole sensor or position sensor of sewing
machine is defective.
Reverse rotation of main shaft motor
When sewing machine motor rotates in reverse
direction.
Power instantaneous cut detection
When input power is instantaneously OFF.
Over voltage
When input power is more than the specified value.
Low voltage
When input voltage is 150V or less.
Abnormality of main shaft motor IPM
When IPM of servo control p.c.b. is abnormal.
Description of error
– 202 –
How to recover Place of recovery
Possible to
Previous
re-start after
screen
reset.
Possible to
Previous
re-start after
screen
reset.
Possible to
Commnunication
rewrite program screen
after pressing
down
communication
switch.
Possible to
Commnunication
rewrite program screen
down
communication
switch.
Turn OFF
the power
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents