(18) Adjusting the thread trimmer sensor

Standard Adjustment
After completion of origin retrieval (at start switch on) in the test mode I07 (IP-400) or CP-6 (CP-20), press the
+ key
6 to 8 times, and the thread trimmer sensor is turned off (IP-400: The contents
on the operation
panel change from "
" to "
", CP-20: The display
of 10th digit on the operation panel changes from
"1" to "0".)
CP-20
C
– 31 –