Error code
E918
E925
E943
E946
E948
Pict
MAIN board overheat
Overheat of MAIN board
Turn ON the power again after taking time.
Intermediate presser motor origin retrieval error
Origin sensor of intermediate presser motor does not
change at the time of origin retrieval.
MAIN EEP-ROM trouble
When data writing to EEP-ROM cannot be
performed.
Defective EEP-ROM writing of HEAD RELAY board
When data writing to EEP-ROM cannot be performed. the power.
F-ROM abnormality
When erase or writing of program cannot be
performed at the time of downloading program.
Description of error
– 204 –
How to recover Place of recovery
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
Turn OFF
the power.